BUSINESS

/Business/Covered Structure Expansion Joint

Covered Structure Expansion Joint

BUSINESS

Covered Structure Expansion Joint

EGIS Joint Construction Method
EGIS Joint Construction Method which is applicable to covered structure expansion joint, prevents crack and Pot-Hole of upper asphalt pavement layer which is occured at ground characteristic changing location, structure's section changing location, secures safety of vehicles and high speed ability. Also, it is possible to feel silent during vehicle driving by Jointless construction. prolong public usage life cycle of expansion joint by induced drain with slab drain for percolating water which is percolated into ascon, prevents see-saw phenomenon (excitation, corrossion, etc) using complementary textile with flexible material.
Characteristics & Advantages of Covered Structure Expansion Joint
Elastic Seal Material Performance for Expansion Joint
Items Criteria Result Judgement Test Method
Cone Penetration (25℃, 150g, 5 Sec.) Under 75 44.7 OK ASTM D 6297
Cone Penetration (-18℃, 200g, 60 Sec.) Over 10 12.8 OK
Elasticity Recovery Rate (25℃, 75g) 40~70% 46.5 OK
Flow Degree (60℃,5hr) Under 3.0 1.21 OK
Asphalt Suitability
(Asphalt Compatible)
All serene All serene OK
Adhesivity (-7℃) All serene All serene OK
Low Temperature Flexibility (-23℃) All serene All serene OK
Softning Point Over 83 93 OK ASTM D 36
Ductility (25℃, 5cm/min) Over 40 45 OK ASTM D 113
Adhesion in Tension - Expansion coefficient at fracture Over 700 727 OK ASTM D 5329
Covered Structure Expansion Joint Construction Example
  • Before Construction

  • Before Construction

  • Before Construction

  • After Construction

  • After Construction

  • After Construction